Flooring Guide: Engineered Wood, Laminate, Underlay & Professional Installation
Choosing a new floor involves more than selecting a colour or wood pattern. The subfloor, moisture conditions, underlay, installation method and room layout all affect the finished result. This guide explains the main options and the preparation behind a well-installed floor.
A new floor can change the feel of an entire property. Natural timber brings warmth and character, engineered wood offers a real wood surface with a layered construction, and laminate provides a wide choice of decorative finishes. Each option has different installation requirements, maintenance considerations and costs.
One of the most important parts of any flooring project is often hidden once the work is complete: the subfloor. If the base is damp, unstable, dusty or uneven, even an expensive floor can develop movement, noise or joint problems. Before ordering materials, inspect the existing floor and confirm that the proposed product is suitable for the room and installation conditions.
Which type of flooring should you choose?
The main options for residential projects include laminate, engineered wood, solid wood and parquet. The right choice depends on the appearance you want, the condition of the property, the level of foot traffic and the maintenance you are prepared to carry out.
Laminate flooring
Laminate flooring is made from a composite core with a printed decorative layer and a protective wear surface. It is available in many wood-effect designs and is often selected for its practical maintenance and range of price points. Most laminate floors are installed as floating click systems over a suitable underlay, although product designs vary.
Laminate is not the same as real timber and damaged boards are not generally sanded and refinished like a solid wood floor. Pay attention to the product's water-resistance claims and the manufacturer's restrictions for kitchens, bathrooms and other areas exposed to moisture.
Engineered wood flooring
Engineered wood has a real timber wear layer bonded to a layered core. This construction can offer greater dimensional stability than a comparable solid wood board, but it remains a natural wood product and responds to changes in temperature and humidity.
It is available in different thicknesses, surface finishes and formats. Depending on the product, it may be installed as a floating floor, fully bonded with adhesive or mechanically fixed. The wear-layer thickness affects how the floor can be maintained or refinished, so check the manufacturer's specifications before buying.
Solid wood flooring
Solid wood boards are made from a single piece of timber. They can be sanded and refinished where sufficient material remains, but they are more sensitive to changes in moisture and environmental conditions than many engineered products. Installation method, subfloor type and room conditions are particularly important.
Parquet, herringbone and chevron flooring
Parquet describes flooring made from smaller pieces arranged in a pattern. Herringbone uses rectangular blocks laid at right angles, while chevron boards are cut or manufactured with angled ends to create a continuous V pattern. These layouts can create a distinctive finish but require accurate setting-out, consistent alignment and careful preparation.
Engineered wood vs laminate vs solid wood
| Floor type | Construction | Main considerations |
|---|---|---|
| Laminate | Decorative surface over a composite core | Practical range of designs; follow moisture restrictions and care instructions. |
| Engineered wood | Real timber wear layer over a layered core | Natural wood appearance; installation and refinishing depend on product construction. |
| Solid wood | Timber throughout the board | Can often be refinished, but moisture and environmental conditions need careful control. |
| Parquet | Small wood blocks or patterned engineered elements | Distinctive pattern; accurate setting-out and installation are essential. |
Subfloor preparation: the foundation of a good floor
The subfloor is the surface that supports the new flooring. It may be concrete, screed, plywood, chipboard or existing timber floorboards. Each type needs to be checked before installation. A new floor should not be expected to hide significant dips, movement, damp or structural defects.
Check that the subfloor is sound
Look for loose boards, squeaks, movement, cracks, crumbling screed, old adhesive and damaged sections. Timber boards may need to be secured, while weak or broken areas may require repair or replacement. Concrete and screed should be sound and suitable for the selected adhesive or floating system.
Check flatness and level
Flooring manufacturers specify how flat the base must be, and tolerances differ between products. Use a suitable straightedge or long level to identify high spots and dips. Localised defects may need sanding, filling or a compatible levelling compound. Do not assume that a thicker underlay will correct an uneven subfloor.
Check moisture before installation
Moisture is a major risk for wood-based flooring. Concrete and screed may retain construction moisture, while timber floors can be affected by leaks, poor ventilation or damp from below. Use an appropriate moisture-testing method for the substrate and compare the results with the flooring and adhesive manufacturers' limits.
If readings are outside the permitted range, investigate the cause and follow the specified moisture-control system. A surface coating or membrane should not be selected without checking compatibility with the substrate, adhesive and flooring product.
Clean the surface thoroughly
Remove dust, grit, loose material and contamination. Adhesive systems may require a specific primer and surface preparation. A floating system still needs a clean, stable base so that debris does not create noise or damage the underside of the flooring.
Underlay: what does it do and when do you need it?
Underlay is a layer installed between the subfloor and certain floor coverings. Depending on its design, it can help with acoustic performance, thermal insulation, minor surface texture and moisture management. It must be compatible with the flooring system and the subfloor.
Underlay for laminate flooring
Most laminate products require an underlay unless an integrated backing is specified. Underlay type and thickness should match the manufacturer's requirements. Some products require a separate damp-proof membrane over mineral subfloors, while others use an underlay with an integrated moisture barrier. Joints and overlaps must be treated as specified.
Underlay for floating engineered wood
Floating engineered wood floors commonly use a suitable acoustic or combination underlay. The product must be designed for the floor's locking or joint system and the subfloor beneath it. An underlay that is too soft or too thick can allow excessive movement and put stress on the joints.
Does glue-down engineered wood need underlay?
A fully bonded engineered wood floor is normally fixed directly to a suitable prepared subfloor using the specified flooring adhesive. It is not installed as a floating floor over a compressible underlay. The adhesive, primer and any moisture-control products must form a compatible system.
Floating vs glue-down flooring: what is the difference?
The installation method affects the feel of the floor, the preparation required and the materials used. The flooring manufacturer may permit one method or several methods for a particular product.
Floating installation
With a floating floor, the boards are joined to one another rather than fixed directly to the subfloor. Many laminate and click-fit engineered floors use this method. A suitable underlay is normally installed beneath the floor unless the product has an integrated backing and its instructions state otherwise.
Floating floors need the specified expansion gaps around walls, door frames, pipes and other fixed objects. Large continuous areas or connected rooms may need additional movement joints or transition profiles.
Glue-down installation
With a glue-down system, the flooring is bonded directly to a suitable subfloor using a compatible flooring adhesive. This method is commonly used for certain engineered wood and parquet products. It requires careful subfloor preparation, moisture checks, correct adhesive selection and the specified trowel and application method.
Which method is best?
There is no single best method for every project. The choice depends on the flooring product, subfloor construction, room conditions, acoustic requirements and manufacturer's instructions. Do not choose a method based only on whether it appears quicker or uses fewer materials.
Expansion gaps and movement joints
Wood and laminate flooring can expand and contract as temperature and humidity change. Floating floors therefore need space to move at the perimeter and around fixed objects. The required gap depends on the product, room dimensions and installation instructions.
Skirting boards, scotia or suitable trim can cover perimeter gaps, but they should not trap the floor or prevent movement. Doorways, narrow passages, large connected areas, pipes and columns may need additional detailing or transition profiles. Follow the flooring manufacturer's layout requirements.
How to install engineered wood flooring
Once the subfloor has passed the required checks and the installation method has been confirmed, the work can be planned. The exact sequence varies between floating, nailed and glue-down products.
- Check the site conditions: confirm that wet trades are complete, the building is weather-tight and room conditions meet the product requirements.
- Inspect the delivery: check product, grade, dimensions, finish and quantity before installation. Report damage or discrepancies to the supplier.
- Follow acclimatisation instructions: store the flooring in the conditions and for the period specified by the manufacturer. Not all products have the same requirements.
- Prepare the subfloor: complete moisture, flatness and stability checks, and carry out the required repairs, priming or moisture treatment.
- Plan the layout: measure the room, consider the direction of the boards, set out starting lines and avoid very narrow finishing strips where possible.
- Blend boards where appropriate: mix boards from several packs as recommended to distribute natural colour and grain variation.
- Install using the specified system: fit the underlay for a floating floor or apply the approved adhesive for a glue-down system.
- Maintain movement allowances: use spacers and form expansion gaps and transition details as required.
- Complete edges and thresholds: fit suitable profiles and trims without restricting floor movement.
- Protect the finished floor: follow the manufacturer's guidance for cleaning, curing, furniture placement and protection during other building work.
How to lay laminate flooring
Laminate is commonly installed as a floating click system. The subfloor should be clean, dry, stable and within the manufacturer's flatness tolerance. Use the correct underlay and moisture barrier for the substrate, unless the product specifies an integrated solution.
- Remove existing floor coverings where required and inspect the base.
- Secure loose timber boards and repair uneven or damaged areas.
- Check moisture and install any specified damp-proof membrane.
- Lay compatible underlay with joints treated as instructed.
- Plan the board direction and stagger end joints according to the product guidance.
- Fit boards using the manufacturer's locking method and suitable tools.
- Maintain perimeter gaps and install transition profiles where required.
- Fit skirting or trims and clean the surface using the recommended method.
Some laminate products have integrated underlay or special requirements for underfloor heating. Always use the instructions supplied with the exact product rather than assuming that every click floor is installed in the same way.
Can an existing timber floor be sanded and refinished?
In some cases, an existing timber floor can be restored rather than replaced. Sanding removes the worn surface layer and prepares the timber for a new finish, such as lacquer, oil or hardwax oil. Whether this is possible depends on the floor construction, remaining wear layer, previous treatments and condition of the boards.
Inspect the floor before sanding
Check for loose boards, movement, deep stains, water damage, previous repairs and protruding nails or fixings. Engineered flooring can only be sanded within the limits of its real timber wear layer. Some veneer products are not designed for sanding at all.
Choose the right finish
Lacquer, oil and hardwax oil create different appearances and maintenance requirements. The choice should suit the timber, the existing coating and the expected use of the room. Follow the finish manufacturer's preparation, application and curing instructions.
Common flooring problems and how to prevent them
| Problem | Possible cause | Prevention |
|---|---|---|
| Floor feels bouncy | Uneven or flexible subfloor, unsuitable underlay or incorrect installation | Check the base and use the specified installation system. |
| Gaps between boards | Movement, poor joint engagement or changing moisture conditions | Prepare the room correctly and follow fitting and environmental guidance. |
| Floor edges lift or peak | Insufficient expansion space, moisture or restricted movement | Check moisture and provide the required movement allowances. |
| Squeaking or clicking sounds | Loose subfloor, debris, friction or movement at joints | Secure and clean the subfloor before installation. |
| Joints become damaged | Uneven base, excessive movement or underlay that is too soft | Meet the product's flatness requirements and select compatible underlay. |
| Boards swell or distort | Water ingress, excess moisture or unsuitable room conditions | Resolve moisture sources and follow the product's use restrictions. |
| Adhesive failure | Incompatible adhesive, damp or poorly prepared subfloor | Use an approved adhesive system on a correctly prepared base. |
How much flooring should you order?
Measure the length and width of each room and calculate its area. Add the room areas together, then allow an additional quantity for cutting, board selection and the flooring pattern. The amount of extra material depends on the product, room shape, installation layout and supplier guidance.
For a straightforward rectangular room, area is calculated by multiplying length by width. For example, a room measuring 5 metres by 4 metres has a floor area of 20 square metres. Hallways, alcoves, bay areas and irregular rooms should be measured separately and added to the total.
Herringbone and chevron layouts can require more cutting and careful selection than a straight plank layout. Confirm the recommended waste allowance with the flooring supplier before ordering. It is also sensible to retain spare boards from the same batch for future repairs, where possible.
What affects the cost of a flooring project?
The total cost is influenced by more than the price per square metre of the flooring. A reliable estimate should distinguish materials, preparation and installation labour so that the scope is clear.
| Cost area | What may be included |
|---|---|
| Flooring material | Laminate, engineered wood, solid wood or parquet boards. |
| Subfloor preparation | Repairs, securing boards, sanding high spots or compatible levelling products. |
| Moisture management | Testing and any specified damp-proof or moisture-control system. |
| Underlay or adhesive | Product-specific underlay for floating floors or approved adhesive for bonded systems. |
| Installation labour | Setting out, cutting, fitting, detailing and finishing. |
| Trims and finishing | Skirting, scotia, thresholds, transition profiles and door adjustments where required. |
| Waste and disposal | Removal of old floor coverings, packaging and waste, where included in the agreed scope. |
Before work starts, agree who is supplying the flooring and associated materials, what preparation is included, how waste will be handled and whether door trimming or skirting replacement is required. This helps avoid misunderstandings and makes quotes easier to compare.
Planning flooring work in London homes
London properties can have a wide range of subfloor constructions, from suspended timber floors in period homes to concrete or screeded bases in newer flats. Older properties may also have uneven floorboards, previous repairs, different floor heights between rooms or restricted access for material deliveries.
For larger projects, plan the work room by room and check how the new floor will meet existing tiles, carpet, stairs and thresholds. In flats, consider building management rules, delivery access, noise restrictions and the need to protect shared areas. Confirm any underfloor heating requirements before choosing the flooring system.
Flooring FAQs
Is engineered wood flooring better than laminate?
Neither is automatically better. Engineered wood has a real timber wear layer, while laminate has a decorative surface over a composite core. Compare appearance, cost, maintenance, moisture restrictions and the product's installation requirements.
Does engineered wood flooring need underlay?
It depends on the installation method. Floating engineered floors commonly use a suitable underlay. Fully bonded glue-down floors are fixed directly to the prepared subfloor with the specified adhesive and do not normally use floating-floor underlay.
Does laminate flooring need underlay?
Most laminate systems require a compatible underlay unless an integrated backing is specified. The underlay should match the product and subfloor, and it should not be used to conceal significant unevenness.
Does a subfloor need to be level?
Yes. It must meet the flooring manufacturer's requirements for flatness, stability and cleanliness. High spots, dips, loose boards and defects should be addressed before installation.
Do wood floors need expansion gaps?
Most floating wood and laminate floors require perimeter expansion gaps and sometimes additional movement joints. The required dimensions and locations depend on the product and room layout.
Can engineered wood flooring be glued down?
Many engineered wood products can be fully bonded to a suitable prepared subfloor using the specified flexible flooring adhesive. Check the product and adhesive instructions before choosing this method.
Conclusion: the best flooring starts underneath
The appearance of a new floor matters, but its long-term performance depends on the preparation beneath it. Choose a product that suits the room, check the subfloor carefully, manage moisture, select the correct underlay or adhesive and allow for natural movement. A well-planned installation creates a cleaner finish and helps reduce problems after the room is back in use.
Sources and further guidance
- National Institute of Carpet and Floorlayers (NICF) – Guide to Domestic Flooring.
- Wood Flooring Association (WFA) – Engineered plank flooring, glue-down installation guidelines.
- Wickes – How to lay laminate flooring.
- Screwfix – How to apply underlay for laminate flooring.
- B&Q – Preparing to lay laminate and real wood flooring.
- Quick-Step – Flooring installation and subfloor guidance.
Always follow the current installation instructions for the exact flooring product, underlay, adhesive and subfloor system. Moisture limits, flatness tolerances, acclimatisation periods, expansion gaps and permitted installation methods vary. The guidance in this article is general and does not replace product-specific instructions or a site assessment.